Technacal Specification | |
ECG | |
Number of Leads | 3 or 5 leads |
Lead View | User Slectable:I,II,III,aVR,aVL,aVF,V(5 Lead);I,II or III(3 lead) |
Gain Slection | x1/4,x1/2,x1 and x2 |
Frequency Response |
Diagnostic:0.05 to 90HZ Monitor:0.5 to 35 HZ Surgery:1-15HZ Strong:5-15HZ |
Arrhythmia analysis | 13 Kinds |
Electrosurgery Protection | Yes |
Defibrillator | Yes |
Pacer Dection/Rejection | Yes |
Pulse Oxemetry | |
Range | 1% to 99% |
Resolution | 1% |
Accuracy |
70% to 99% range ±2% 50 to 69%;undefined |
Method | Dual wavelength LED |
Heart(Pulse) Rate | |
Source | User Slectable:Smart,ECG,Pleth,NIBP |
Range | 20 to 300 bpm(30-240 bpm NIBP) |
Accurancy |
±1bpm or ±1%(ECG)whichever is greater 2bpm or ±2%(NIBP)whichever is greater |
NIBP(Non-Invasive Blood Presure) | |
Technique | Oscillometric during inflation |
Range |
Adu:40-270mmHg Ped:40-240mmHg Neo:40-135mmHg |
Measurment cycle | <40 sec,typical |
Automatic Measurement | |
Cycles(Selectable) | 2,3,5,10,15,30min 1,2,4hr |
STAT model | 5 minutes of continuous reading |
Max Allowable Cuff Presure |
Adu:300 mmHg Ped:240 mmHg Neo:150 mmHg |
Resolution | 1mmHg |
Transducer Accurancy | ±2mmHg or±2% of reading |
Temperature | |
Channels | 2 |
Range,Accuracy | 68°-113°F(20°-45℃):±0.1℃ |
Display Resolution | ±0.1℃ |
Proble | YSI 400 and YSI 700 Series |
Capnography(CO2) | |
Gas Type | Range & Accuracy |
CO2 | 0 - 10% ; ±(0.2 vol% +2% of reading) |
10- 15% ; ± (0.3 vol% +2% of reading) | |
ISO | 0 - 6% ; +2% of reading) |
ENF,HAL | 0 - 6% ; +2% of reading) |
DES | 0 - 18% ; +2% of reading) |
SEV | 0 - 8% ;+2% of reading) |
Respiration Rate | |
Rate: | 7-120 bpm(ECG);2 to 120(CO2) |
Resolution | 1 breath/min |
Accuracy | ± 2 breath/min |
Trends | |
Memory | 96 hr at 30 second intervals for a NIBP reading every 5 mintues |
Display | trabular;graphical |
Interface & Display | |
Keys | 9;memberance activated |
Rotary Knob | Push or rotate;24 steps/turn |
Screen | 12,1 inch active color TFT |
Resolution | Internal Display 800*600 pixels |
Waveforms | 9 Maxinum |
Waveform Types | ECG Leads,I,II,III,aVR,aVL,aVF,V,Respiraion,CO2,Pletch |
Sweep Speed | 6.25,12.5,25 or 50 mm/sec |
Languages | English;Chinese |
Printer(option) | |
Type | Thermal printer |
Paper Speed | 25 or 50 mm/sec |
Physical Properties | |
Weight | 5 Kg |
Size |
11(H)*13(W)*10.3(D)inch 28(H)*33(W)*26.2(D)cm |
Power Requirement | |
Voltage | AC100-240V,50/60HZ |
Power Consumption | 35W |
Battery | 1 sealed lithium battery |
Battery Life | 3 hour typical |
Recharge time | 4.5 hours |
Environmental | |
Operating Temperature | 59°--95°F(15°--35℃) |
Storage Temperature | 23°--122°F(-5°--50℃) |
Humidity | 15% to 90% |